title: Well Test
slug: well-test
docTags: 
createdAt: 2024-03-28T22:43:49.364Z
---

The Well Test table stores individual well test measurements. Well tests overlay on production charts and can be compared with allocated volumes. The **uwi** field must match a uwi in the [Well](docId\:P-xHbe4jqKJQemay7aOL5) table.

The table supports a variety of test types: WELLTEST, TRACER, CGR, and SALINITY. The default is WELLTEST, a standard production volume measurement through a test separator.

The unique constraint on well test entries is **uwi + sourceId**. If **sourceId** is not supplied, the test's **date** is used as its sourceId — so clients that never send sourceId effectively get one test per well per date, and re-posting the same date upserts it.

| **Variable**            | **Data Type**   | **Unit of Measure** | **Is Nullable?** | **Default Value** | **Description**                                                                                                               |
| ----------------------- | --------------- | ------------------- | ---------------- | ----------------- | ----------------------------------------------------------------------------------------------------------------------------- |
| uwi                     | String          | -                   | No               | -                 | Unique Well Identifier. Must match the uwi of a record in the [Well](docId\:P-xHbe4jqKJQemay7aOL5) table.                     |
| sourceId                | String          | -                   | Yes              | date              | Unique identifier of the test. Enables upsert from a source system of record. If not specified, the test's date is used.      |
| date                    | Datetime Offset | -                   | No               | -                 | Test date. Datetime offset (with timezone) in ISO 8601 format. Example: 2022-09-27T16:28:37+0000                              |
| type                    | String          | -                   | Yes              | WELLTEST          | Type of the well test:<br /><br />WELLTEST - standard measurement through a test separator<br />TRACER<br />CGR<br />SALINITY |
| isValid                 | Boolean         | -                   | Yes              | True              | Whether the well test is valid. Invalid tests are stored but excluded from analysis.                                          |
| oilRate                 | Double          | STB/d               | Yes              | -                 | Oil rate                                                                                                                      |
| gasRate                 | Double          | Mscf/d              | Yes              | -                 | Gas rate                                                                                                                      |
| waterRate               | Double          | STB/d               | Yes              | -                 | Water rate                                                                                                                    |
| tubingPressure          | Double          | psig                | Yes              | -                 | Tubing / wellhead pressure                                                                                                    |
| tubingTemperature       | Double          | degF                | Yes              | -                 | Tubing / wellhead temperature                                                                                                 |
| casingPressure          | Double          | psig                | Yes              | -                 | Casing pressure                                                                                                               |
| casingTemperature       | Double          | degF                | Yes              | -                 | Casing temperature                                                                                                            |
| gaugePressure           | Double          | psig                | Yes              | -                 | Downhole gauge pressure (a downhole gauge must exist in the downhole equipment table)                                         |
| gaugeTemperature        | Double          | degF                | Yes              | -                 | Downhole gauge temperature (a downhole gauge must exist in the downhole equipment table)                                      |
| choke                   | Double          | %                   | Yes              | -                 | Choke opening                                                                                                                 |
| upstreamChokePressure   | Double          | psig                | Yes              | -                 | Upstream choke pressure                                                                                                       |
| downstreamChokePressure | Double          | psig                | Yes              | -                 | Downstream choke pressure                                                                                                     |
| basicSedimentAndWater   | Double          | %                   | Yes              | -                 | Basic sediment and water percentage                                                                                           |
| duration                | Double          | hrs                 | Yes              | -                 | Well test duration                                                                                                            |
| separatorPressure       | Double          | psig                | Yes              | -                 | Test separator pressure                                                                                                       |
| separatorTemperature    | Double          | degF                | Yes              | -                 | Test separator temperature                                                                                                    |
| gasLiftInjectionRate    | Double          | Mscf/d              | Yes              | -                 | Gas lift injection rate during the test                                                                                       |
| waterGasRatio           | Double          | STB/MMscf           | Yes              | -                 | Water/gas ratio measured by the test                                                                                          |
| condensateGasRatio      | Double          | STB/MMscf           | Yes              | -                 | Condensate/gas ratio measured by the test                                                                                     |
| salinity                | Double          | ppm                 | Yes              | -                 | Salinity measured by the test                                                                                                 |

***

# Data Integrity Checks

| **Condition**                        | **Response**               |
| ------------------------------------ | -------------------------- |
| uwi is NULL or empty                 | Record Rejected            |
| uwi does not exist in the Well table | Record Rejected            |
| type is NULL or empty                | Value defaults to WELLTEST |
| isValid is NULL or empty             | Value defaults to True     |
| sourceId is NULL or empty            | Value defaults to the date |

***

# Common Error Messages

| **API**                | **Scenario** | **Error Response**              |
| ---------------------- | ------------ | ------------------------------- |
| Add / Upsert well test | Unknown UWI  | Well with uwi xxx was not found |